Energy Modeling

How Does 179D Energy Modeling Actually Work?

The ordinary comparison is not simply the building before and after renovation. It uses an as-installed model and a prescribed reference building.

Last reviewed: September 17, 2026

Section 179D | Energy Modeling | ASHRAE

An ordinary energy-efficient commercial building property analysis creates two digital versions of the same building. One represents proposed or as-installed systems; the other follows the applicable American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) reference rules.

Qualified software calculates covered annual energy and power costs under a consistent comparison. Utility bills can provide context, but they do not replace this statutory modeling test.

Two models

Hold comparison assumptions consistent

Geometry, occupancy, schedules, climate, and other prescribed assumptions must follow the applicable method. System inputs change where the rules require the proposed and reference buildings to differ.

The model is not a free-form forecast. Preserve the software name and version, input files, output reports, and reviewer decisions.

Illustrative covered annual costs

HVAC/hot water and lighting combine into the modeled totals.

Reference building$200,000

$150,000 HVAC/hot water + $50,000 lighting

Proposed building$140,000

$110,000 HVAC/hot water + $30,000 lighting

Invented data illustrate a 30% reduction; they do not predict any equipment package.
Illustrative covered annual costs: accessible data
ItemValueNote
Reference building$200,000$150,000 HVAC/hot water + $50,000 lighting
Proposed building$140,000$110,000 HVAC/hot water + $30,000 lighting

Reference edition

Choose the federal baseline from project dates

Announcement 2024-24 identifies ASHRAE 90.1-2007 for 2015-2026 service dates, 90.1-2019 for 2027-2028, and 90.1-2022 after 2028, with a rule allowing 90.1-2007 for property whose construction began before 2023.

Local code compliance and the federal tax baseline are related engineering contexts but not automatic substitutes.

Covered costs

Convert modeled energy into the defined annual-cost comparison

Assume reference HVAC/hot water costs of $150,000 and lighting costs of $50,000, totaling $200,000. Proposed costs of $110,000 and $30,000 total $140,000. The illustrative reduction is ($200,000 − $140,000) ÷ $200,000 = 30%.

At 30% for a tax year beginning in 2026, preliminary rates are $0.69 base or $3.57 increased. Those rates remain subject to every path and amount requirement.

Input-to-certification path

Installed facts can require a model update before certification.

Plans

Systems and schedules

Qualified software

Reference comparison

Field inspection

Observe installation

Signed evidence

Reconcile and certify

Simplified ordinary-route workflow.

Installed building

Field evidence feeds back into the final model

Substituted equipment, revised controls, changed glazing, and actual operating details can alter model inputs. The ordinary-route field inspection occurs after the property is placed in service and supports reconciliation to installed conditions.

A modeler, designer, and certifier need not be the same person. The applicable guidance requires an unrelated, appropriately licensed engineer or contractor for ordinary-route certification.

Model record

A reviewer should be able to reproduce the comparison logic.

Review pointEvidence or measureWhy it matters
Reference selectionEdition + reasonService and construction dates support the choice.
SoftwareName + versionConfirm the version on the DOE list.
Installed inputsSource recordTie schedules, submittals, and observations to assumptions.
A complete certification includes additional requirements.

Prepare the review

Organize model-ready records

  • Construction-start and service dates
  • Applicable ASHRAE edition
  • Qualified software and version
  • Geometry and area source
  • HVAC/hot-water inputs
  • Lighting and controls inputs
  • Envelope assemblies
  • Schedules and operating assumptions
  • Field changes and inspection support
  • Signed certification and tax limits

Common questions

Practical answers before the review

Is the reference building the old building?

No. It is a prescribed comparison model under the applicable federal method.

Can utility bills replace the ordinary model?

No. Existing utility bills alone do not establish the ordinary reference-building test.

Why does software version matter?

The analysis must use qualified software and an applicable version and method.